Comprehensive services in areas of testing, inspection, certification and training.

Certification with the EHPA Quality Label

The QL quality label for heat pumps originates from the activities of the heat pump associations of Austria, Germany, and Switzerland, which created a common set of requirements to ensure the quality of products and services.

The EHPA‑QL quality label is a European quality assessment system for heat pumps, developed by national associations and further expanded by the European Heat Pump Association (EHPA).

Its aim is to confirm that a given heat pump meets strict requirements for performance, efficiency, and service quality. The label is granted based on independent testing in accredited laboratories according to international standards (e.g., EN 14511, EN 14825 or EN 16147), as well as an evaluation of the manufacturer’s service infrastructure in the specific country.

EHPA‑QL now has Europe‑wide reach and is awarded in 12–13 countries across the continent.

The QL label can be granted to standardised space heating electrically-driven heat pumps, with or without domestic hot water heating capability, with a capacity up to 100 kW from air, geothermal or water heat sources. In order to qualify for the label, the heat pump in question must comply with EHPA heat pump test criteria and the distributor must provide a defined level of service.

The key requirements are:

Minimum requirements for SCOP of heat pumps for space heating in average climate conditions using low temperature application according to ČSN EN 14825 (SCOP)

air/air

3,40

air/water

3,50

brine/water

4,30

water/water

4,30

DX/water

4,10

exhaust air/water

3,50

Minimum SCOP requirements for heat pumps intended for heating in an average climate under medium‑temperature application according to EN 14825 (SCOP).

air/water

3,00
brine/water 3,38
water/water 3,38
direct expansion/water 3,38

Minimum requirement for domestic hot water heat pumps according to ČSN EN 16147:

Minimum reference hot water temperature  θ’WH 52 °C

Minimum  COP DWHvalues for an average temperature climate

outdoor air (A7) 2,80
unheated indoor air (A15) 2,90
indoor air (A20) 3,20
exhaust air (A20) 3,20
water (W10) 3,00
brine (B0) 2,80

Source:EHPA Quality Label - European Heat Pump Association 

SZU as an accredited testing laboratory recognized by the EHPA offers testing in the full range of EHPA requirements for all heat pumps except for air / air units.

Asociace pro využití tepelných čerpadel - Heat Pump Association - AVTČ, is entitled to grant certificates (Q labels) in the Czech Republic. It is made based on application, inspection of test reports and test certificates issued by a recognized testing laboratory, inspection of documentation and other required documents. Such certificate can also be used when applying for subsidy programs in some European countries.

Who can you reach out to?

Ing. Dominik Šedivý, Ph.D.

Ing. Dominik Šedivý, Ph.D.

Heat Pumps and Cooling Equipment Specialist

sedivy@szutest.cz
+420 541 120 439
+420 702 127 557

interest

Are you interested in this service?

1.

Inquiry

If you are interested in any of our services, please contact us.

slide

2.

Specification

Our experts will contact you soon and specify the details of your inquiry.

slide

3.

Offer

After clarifying the details we will prepare a final offer for you.

slide

4.

Order

You will then fill in a binding order.

slide

5.

realization

After signing the contract, we will start to execute your order.

references

news

blog

we will increase the credibility of your products

newsletter

Subscribe to our newsletter

News from the world of testing, inspection and certification